diff options
author | Denis Shienkov <denis.shienkov@gmail.com> | 2013-06-07 18:56:57 +0400 |
---|---|---|
committer | The Qt Project <gerrit-noreply@qt-project.org> | 2013-06-07 18:06:13 +0200 |
commit | 58365228b3181ed03188fc8ff56007ea22678bb5 (patch) | |
tree | cb97267b29c1b323bcbc30803f47afe4c5682d37 /README | |
parent | 2bcac223e64599eb74889975053f6547000b13cb (diff) |
Windows: Fix no longer receive data after EV_TXEMPTY triggered for CDC ACM devicev5.1.0-rc2v5.1.0-rc1v5.1.0
A previous patch
* SHA1 ID: 2bcac223e64599eb74889975053f6547000b13cb
introduced a regression: after triggering of EV_TXEMPTY a reception of
data is stopped. The reason for this was an immediate return from the
handler processCompletionRoutine().
The solution - do not do an immediate return and let to call method
startAsyncRead().
Thanks to Dan
Task-number: QTPLAYGROUND-22
Change-Id: I1a6b358e6bbaba94527dc9db98a2ab046a8c6f05
Reviewed-by: Sergey Belyashov <Sergey.Belyashov@gmail.com>
Reviewed-by: Laszlo Papp <lpapp@kde.org>
Diffstat (limited to 'README')
0 files changed, 0 insertions, 0 deletions