summaryrefslogtreecommitdiffstats
path: root/chromium/third_party/cygwin/lib/perl5/5.10/sigtrap.pm
diff options
context:
space:
mode:
Diffstat (limited to 'chromium/third_party/cygwin/lib/perl5/5.10/sigtrap.pm')
-rw-r--r--chromium/third_party/cygwin/lib/perl5/5.10/sigtrap.pm289
1 files changed, 0 insertions, 289 deletions
diff --git a/chromium/third_party/cygwin/lib/perl5/5.10/sigtrap.pm b/chromium/third_party/cygwin/lib/perl5/5.10/sigtrap.pm
deleted file mode 100644
index 8577c728c78..00000000000
--- a/chromium/third_party/cygwin/lib/perl5/5.10/sigtrap.pm
+++ /dev/null
@@ -1,289 +0,0 @@
-package sigtrap;
-
-=head1 NAME
-
-sigtrap - Perl pragma to enable simple signal handling
-
-=cut
-
-use Carp;
-
-$VERSION = 1.04;
-$Verbose ||= 0;
-
-sub import {
- my $pkg = shift;
- my $handler = \&handler_traceback;
- my $saw_sig = 0;
- my $untrapped = 0;
- local $_;
-
- Arg_loop:
- while (@_) {
- $_ = shift;
- if (/^[A-Z][A-Z0-9]*$/) {
- $saw_sig++;
- unless ($untrapped and $SIG{$_} and $SIG{$_} ne 'DEFAULT') {
- print "Installing handler $handler for $_\n" if $Verbose;
- $SIG{$_} = $handler;
- }
- }
- elsif ($_ eq 'normal-signals') {
- unshift @_, grep(exists $SIG{$_}, qw(HUP INT PIPE TERM));
- }
- elsif ($_ eq 'error-signals') {
- unshift @_, grep(exists $SIG{$_},
- qw(ABRT BUS EMT FPE ILL QUIT SEGV SYS TRAP));
- }
- elsif ($_ eq 'old-interface-signals') {
- unshift @_,
- grep(exists $SIG{$_},
- qw(ABRT BUS EMT FPE ILL PIPE QUIT SEGV SYS TERM TRAP));
- }
- elsif ($_ eq 'stack-trace') {
- $handler = \&handler_traceback;
- }
- elsif ($_ eq 'die') {
- $handler = \&handler_die;
- }
- elsif ($_ eq 'handler') {
- @_ or croak "No argument specified after 'handler'";
- $handler = shift;
- unless (ref $handler or $handler eq 'IGNORE'
- or $handler eq 'DEFAULT') {
- require Symbol;
- $handler = Symbol::qualify($handler, (caller)[0]);
- }
- }
- elsif ($_ eq 'untrapped') {
- $untrapped = 1;
- }
- elsif ($_ eq 'any') {
- $untrapped = 0;
- }
- elsif ($_ =~ /^\d/) {
- $VERSION >= $_ or croak "sigtrap.pm version $_ required,"
- . " but this is only version $VERSION";
- }
- else {
- croak "Unrecognized argument $_";
- }
- }
- unless ($saw_sig) {
- @_ = qw(old-interface-signals);
- goto Arg_loop;
- }
-}
-
-sub handler_die {
- croak "Caught a SIG$_[0]";
-}
-
-sub handler_traceback {
- package DB; # To get subroutine args.
- $SIG{'ABRT'} = DEFAULT;
- kill 'ABRT', $$ if $panic++;
- syswrite(STDERR, 'Caught a SIG', 12);
- syswrite(STDERR, $_[0], length($_[0]));
- syswrite(STDERR, ' at ', 4);
- ($pack,$file,$line) = caller;
- syswrite(STDERR, $file, length($file));
- syswrite(STDERR, ' line ', 6);
- syswrite(STDERR, $line, length($line));
- syswrite(STDERR, "\n", 1);
-
- # Now go for broke.
- for ($i = 1; ($p,$f,$l,$s,$h,$w,$e,$r) = caller($i); $i++) {
- @a = ();
- for (@args) {
- s/([\'\\])/\\$1/g;
- s/([^\0]*)/'$1'/
- unless /^(?: -?[\d.]+ | \*[\w:]* )$/x;
- s/([\200-\377])/sprintf("M-%c",ord($1)&0177)/eg;
- s/([\0-\37\177])/sprintf("^%c",ord($1)^64)/eg;
- push(@a, $_);
- }
- $w = $w ? '@ = ' : '$ = ';
- $a = $h ? '(' . join(', ', @a) . ')' : '';
- $e =~ s/\n\s*\;\s*\Z// if $e;
- $e =~ s/[\\\']/\\$1/g if $e;
- if ($r) {
- $s = "require '$e'";
- } elsif (defined $r) {
- $s = "eval '$e'";
- } elsif ($s eq '(eval)') {
- $s = "eval {...}";
- }
- $f = "file `$f'" unless $f eq '-e';
- $mess = "$w$s$a called from $f line $l\n";
- syswrite(STDERR, $mess, length($mess));
- }
- kill 'ABRT', $$;
-}
-
-1;
-
-__END__
-
-=head1 SYNOPSIS
-
- use sigtrap;
- use sigtrap qw(stack-trace old-interface-signals); # equivalent
- use sigtrap qw(BUS SEGV PIPE ABRT);
- use sigtrap qw(die INT QUIT);
- use sigtrap qw(die normal-signals);
- use sigtrap qw(die untrapped normal-signals);
- use sigtrap qw(die untrapped normal-signals
- stack-trace any error-signals);
- use sigtrap 'handler' => \&my_handler, 'normal-signals';
- use sigtrap qw(handler my_handler normal-signals
- stack-trace error-signals);
-
-=head1 DESCRIPTION
-
-The B<sigtrap> pragma is a simple interface to installing signal
-handlers. You can have it install one of two handlers supplied by
-B<sigtrap> itself (one which provides a Perl stack trace and one which
-simply C<die()>s), or alternately you can supply your own handler for it
-to install. It can be told only to install a handler for signals which
-are either untrapped or ignored. It has a couple of lists of signals to
-trap, plus you can supply your own list of signals.
-
-The arguments passed to the C<use> statement which invokes B<sigtrap>
-are processed in order. When a signal name or the name of one of
-B<sigtrap>'s signal lists is encountered a handler is immediately
-installed, when an option is encountered it affects subsequently
-installed handlers.
-
-=head1 OPTIONS
-
-=head2 SIGNAL HANDLERS
-
-These options affect which handler will be used for subsequently
-installed signals.
-
-=over 4
-
-=item B<stack-trace>
-
-The handler used for subsequently installed signals outputs a Perl stack
-trace to STDERR and then tries to dump core. This is the default signal
-handler.
-
-=item B<die>
-
-The handler used for subsequently installed signals calls C<die>
-(actually C<croak>) with a message indicating which signal was caught.
-
-=item B<handler> I<your-handler>
-
-I<your-handler> will be used as the handler for subsequently installed
-signals. I<your-handler> can be any value which is valid as an
-assignment to an element of C<%SIG>. See L<perlvar> for examples of
-handler functions.
-
-=back
-
-=head2 SIGNAL LISTS
-
-B<sigtrap> has a few built-in lists of signals to trap. They are:
-
-=over 4
-
-=item B<normal-signals>
-
-These are the signals which a program might normally expect to encounter
-and which by default cause it to terminate. They are HUP, INT, PIPE and
-TERM.
-
-=item B<error-signals>
-
-These signals usually indicate a serious problem with the Perl
-interpreter or with your script. They are ABRT, BUS, EMT, FPE, ILL,
-QUIT, SEGV, SYS and TRAP.
-
-=item B<old-interface-signals>
-
-These are the signals which were trapped by default by the old
-B<sigtrap> interface, they are ABRT, BUS, EMT, FPE, ILL, PIPE, QUIT,
-SEGV, SYS, TERM, and TRAP. If no signals or signals lists are passed to
-B<sigtrap>, this list is used.
-
-=back
-
-For each of these three lists, the collection of signals set to be
-trapped is checked before trapping; if your architecture does not
-implement a particular signal, it will not be trapped but rather
-silently ignored.
-
-=head2 OTHER
-
-=over 4
-
-=item B<untrapped>
-
-This token tells B<sigtrap> to install handlers only for subsequently
-listed signals which aren't already trapped or ignored.
-
-=item B<any>
-
-This token tells B<sigtrap> to install handlers for all subsequently
-listed signals. This is the default behavior.
-
-=item I<signal>
-
-Any argument which looks like a signal name (that is,
-C</^[A-Z][A-Z0-9]*$/>) indicates that B<sigtrap> should install a
-handler for that name.
-
-=item I<number>
-
-Require that at least version I<number> of B<sigtrap> is being used.
-
-=back
-
-=head1 EXAMPLES
-
-Provide a stack trace for the old-interface-signals:
-
- use sigtrap;
-
-Ditto:
-
- use sigtrap qw(stack-trace old-interface-signals);
-
-Provide a stack trace on the 4 listed signals only:
-
- use sigtrap qw(BUS SEGV PIPE ABRT);
-
-Die on INT or QUIT:
-
- use sigtrap qw(die INT QUIT);
-
-Die on HUP, INT, PIPE or TERM:
-
- use sigtrap qw(die normal-signals);
-
-Die on HUP, INT, PIPE or TERM, except don't change the behavior for
-signals which are already trapped or ignored:
-
- use sigtrap qw(die untrapped normal-signals);
-
-Die on receipt one of an of the B<normal-signals> which is currently
-B<untrapped>, provide a stack trace on receipt of B<any> of the
-B<error-signals>:
-
- use sigtrap qw(die untrapped normal-signals
- stack-trace any error-signals);
-
-Install my_handler() as the handler for the B<normal-signals>:
-
- use sigtrap 'handler', \&my_handler, 'normal-signals';
-
-Install my_handler() as the handler for the normal-signals, provide a
-Perl stack trace on receipt of one of the error-signals:
-
- use sigtrap qw(handler my_handler normal-signals
- stack-trace error-signals);
-
-=cut